Specifications |
|
Input data |
|
|
Inputs |
P 41000 D1 |
±60 mV, ±90 mV, ±150 mV, ±300 mV, |
Calibrated range selection, |
|
|
±500 mV, ±10 V, factory setting: ±10 V |
|
P 41000 D1-nnn |
60 mV ... 100 V, unipolar/bipolar |
1 to 16 ranges to customer requirements, |
|
|
|
calibrated range selection |
|
P 41100 D1-nnn |
60 mV ... 100 V, unipolar/bipolar |
Fixed setting to customer requirements |
|
|
Input resistance |
Range ≤0.5 V |
Approx. 100 kohms |
|
Range >0.5 V ... 3600V |
>2 Mohms |
|
|
Input capacitance |
Range ≤0.5 V |
Approx. 10 nF |
|
Range >0.5 V |
Approx. 1 nF |
|
|
Overload |
Range ≤10 V |
Limited to 36 V by suppressor diode, permissible continuous current = 20 mA |
|
Range >10 V |
Limited to 150 V by suppressor diode, permissible continuous current = 3 mA |
|
Output data |
|
|
Output |
P 41000 D1 |
20 mA, 10 V unipolar/bipolar |
Calibrated range selection, |
|
|
and 4 ... 20 mA |
factory setting: ±10 V |
|
P 41000 D1-nnn |
20 mA, 10 V unipolar/bipolar |
Calibrated range selection, |
|
|
and/or 4 ... 20 mA |
to customer requirements |
|
P 41100 D1-nnn |
20 mA, 10 V unipolar/bipolar or |
Fixed setting to customer requirements |
|
|
4 ... 20 mA |
|
|
Offset |
Factory setting up to ±150 % |
|
|
Load |
With output current |
≤12 V (600 ohms at 20 mA) |
|
With output voltage |
≤10 mA (1000 ohms at 10 V) |
|
|
Offset error |
<20 µA or 10 mV |
|
|
Residual ripple |
<10 mVrms |
|
Transmission behavior |
|
|
Gain error |
<0.1 % meas. val. |
|
|
Cut-off frequency |
>5 kHz; optional factory setting: 10 Hz |
(–3dB) |
|
|
Common mode |
Input range ≤1 V |
CMRR1) |
Approx. 150 dB (DC/AC: 50 Hz) |
rejection ratio |
|
T-CMRR2) |
Approx. 115 dB (1000 V, tr = 1 µs) |
|
Input range >1 V |
CMRR1) |
DC: approx. 150 dB |
|
|
|
AC 50 Hz: approx. 120 dB |
|
|
Temperature influence 3) |
<0.005 %/K full scale |
|
Power supply |
|
|
Power supply |
20 ... 253 V AC/DC |
AC 48 ... 62 Hz, approx. 2 VA; max. approx. 1.2 W |
|
Isolation |
|
|
Galvanic isolation |
3-port isolation between input, output, power supply |
|
|
Test voltage |
Calibrated range |
10 kV AC across input and output/power supply |
|
selection |
|
Fixed settings |
15 kV AC across input and output/power supply |
|
(Model P411xxD1) |
|
All models |
4 kV AC output to power supply |
|
|
Working voltage |
Calibrated range |
Up to 2200 V AC/DC across input, output, and power supply with overvoltage |
(basic insulation) |
selection |
category III and pollution degree 2 (fast transients max. 13.5 kV) |
to EN 61010-1 |
Fixed settings |
Up to 3600 V AC/DC across input, output, and power supply with overvoltage |
|
(Model P411xxD1) |
category III and pollution degree 2 (fast transients max. 20 kV) |
|
|
Rated insulation |
Calibrated range |
Up to 2200 V AC/DC across input, output, and power supply with overvoltage |
voltage to |
selection |
category III and pollution degree 2 |
EN 50124-1 |
Fixed settings |
Up to 3000 V AC/DC across input, output, and power supply with overvoltage |
|
(Model P411xxD1) |
category III and pollution degree 2 |
|
|
Protection against |
Calibrated range |
Protective separation according to EN 61140 by reinforced insulation in accordance with |
electric shock |
selection |
EN 61010-1 |
|
|
Working voltages with overvoltage category III and pollution degree 2: |
|
|
–up to 1100 V AC/DC across output and power supply |
|
|
–up to 300 V AC/DC across output and power supply |
|
Fixed settings |
Protective separation according to EN 61140 by reinforced insulation in accordance with |
|
(Model P411xxD1) |
EN 61010-1 |
|
|
Working voltages with overvoltage category III and pollution degree 2: |
|
|
–up to 1100 V AC/DC across input and output/power supply |
|
|
–up to 300 V AC/DC across output and power supply |
|
For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. |
|
Standards and approvals |
|
|
EMC4) |
Product standard EN 61326 |
|
Emitted interference: Class B |
|
Immunity to interference: Industry |
|
|
Surge withstand |
5 kV, 1.2/50 µs, to IEC 255-4 (higher values upon request) |
|
Further data |
|
|
MTBF5) |
Approx. 96 years |
|
|
Ambient |
Operation: –10 ... +70 °C |
temperature6) |
Transport and storage: –40 ... +85 °C |
|
|
Design |
Modular housing |
Width 22.5 mm |
|
with screw |
See dimension drawing for other measurements |
|
connectors |
|
|
Protection class |
Housing IP 40, terminals IP 20 |
|
|
Mounting |
Snap-on mounting on 35 mm top-hat rail according to EN 60715 |
|
|
Weight |
Approx. 180 g |
|
|
|
|
1) Common-Mode Rejection Ratio = |
2) Transient Common-Mode Rejection = |
3) Reference temperature for TC specifications = 23 °C, the average TC is always specified |
4) Slight deviations are possible while there is interference |
5) Mean Time Between Failures - MTBF - to EN 61709 (SN 29500). Conditions: stationary operation in well-tended rooms, average ambient temperature 40 °C, no ventilation, continuous operation |
6) Extended working temperature range –25 ... +85 °C on request |