Specifications |
|
Input data |
|
|
Inputs |
P 27000 H1/F1: |
Factory setting ±10 V |
|
Voltage |
Configurable from 20 mV ... 200 V and switchable in calibrated |
|
|
steps 60 mV, 100 mV, 150 mV, 300 mV, 500 mV, 1 V, 5 V, |
|
|
10 V, 100 V, unipolar/bipolar |
|
Current |
Configurable from 0.1 mA ... 100 mA and switchable in calibrated |
|
|
steps 1 mA, 5 mA, 10 mA, 20 mA, 50 mA, unipolar/bipolar |
|
|
and 4 … 20 mA1) |
|
|
Input resistance |
Current input |
Ranges ≤5 mA |
Approx. 100 ohms |
|
|
Ranges >5 mA |
Approx. 5 ohms |
|
Voltage input |
|
Approx. 1 Mohm |
|
|
Overload |
Current input |
Ranges ≤5 mA |
≤100 mA |
|
|
Ranges >5 mA |
≤300 mA |
|
Voltage input |
Ranges ≤500 mV |
Limitation with suppressor diode 36 V, |
|
|
|
max. permitted continuous current ≤20 mA |
|
|
Ranges >500 mV |
Limitation with suppressor diode 250 V, |
|
|
|
max. permitted continuous current ≤3 mA |
|
|
Output data |
|
|
Output |
P 27000 H1/F1: Factory setting ±10 V |
|
20 mA, 5 V, 10 V unipolar/bipolar and |
|
4 ... 20 mA, 1 ... 5 V and 2 ... 10 V calibrated selection |
|
|
Offset |
–100 %, – 50 %, 0 %, 50 %, 100 % span of selected output range |
|
calibrated selection |
|
|
Load |
With output current |
≤12 V (600 ohms at 20 mA) |
|
With output voltage |
≤10 mA (1 kohm at 10 V) 2) |
|
|
Offset error |
20 µA or 10 mV |
|
|
Residual ripple |
<10 mVrms |
|
|
Transmission behavior |
|
|
Adjustment range |
of ZERO potentiometer |
±25 % span of selected output range |
|
|
Adjustment range |
of SPAN potentiometer |
0.33 … 3.30 x end value of selected input range (max. Vin = 200 V) |
|
|
Gain error |
<0.08 % meas. val. |
|
|
Cut-off frequency |
P 27000 H1/F1: >10 kHz, <10 Hz switchable –3 dB, fixed-setting models >10 kHz –3 dB |
|
|
Temperature coefficient 3) |
<0.005 %/K full scale (reference temperature 23 °C) |
|
|
Power supply |
|
|
Power supply |
20 ... 253 V AC/DC; AC 48 ... 62 Hz, approx. 2 VA; DC approx. 0.9 W |
|
|
Isolation |
|
|
Galvanic isolation |
3-port isolation between input, output and power supply |
|
|
Test voltage |
5 kV AC input against output and power supply; 4 kV AC output against power supply |
|
|
Working voltage |
1000 V AC/DC with overvoltage category II and pollution degree 2 according to EN 61010-1 |
(basic insulation) |
For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. |
|
|
Protection against |
Protective separation according to EN 61140 by reinforced insulation in accordance with |
electric shock |
EN 61010-1. |
|
Working voltages with overvoltage category II and pollution degree 2 for working voltages: |
|
up to 600 V AC/DC across input and output |
|
up to 300 V AC/DC across output and power supply |
|
up to category II and degree 2 |
|
For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. |
|
|
Standards and approvals |
|
|
Surge withstand |
5 kV 1.2 / 50 µs according to IEC 255-4 |
|
|
EMC 4) |
EN 61326 |
|
|
Approvals |
cUL: |
File No. E 216767, Standards UL 3101-1, CSA-C 22.2, No. 10101-1 |
|
GL: |
No. 42843-02 HH |
|
KTA: |
3507 |
|
|
Other data |
|
|
MTBF 5) |
Approx. 76 years |
|
|
Ambient temperature |
Operation: |
–10 ... +70 ºC |
|
Transport and storage: |
–40 ... +85 ºC |
|
|
Design |
Modular housing, width 12.5 mm, see dimension drawing for other dimensions |
|
Pluggable screw terminals: |
Type H1 |
|
Fixed screw terminals: |
Type F1 |
|
|
Protection class |
IP 20 |
|
|
Mounting |
Metal lock for mounting on 35-mm top-hat rail according to EN 50022 |
|
See dimension drawings for conductor cross section |
|
|
Weight |
Approx. 150 g |
|
|
|
1) Input 4 to 20 mA: Offset switching not calibrated |
2) Higher output load on request |
3) Average TC in specific working temperature range –10 ºC ... +70 ºC |
4) Slight deviations are possible during interference |
5) Mean Time Between Failures - MTBF - to EN 61709 (SN 29500).Conditions: stationary operation in well-tended rooms, average ambient temperature 40 °C, no ventilation, continuous operation |
|