产品 |
|
|
|
|
SS31+E2001型氧量分析仪 |
SS31型测氧探头制作工艺独一无二,无漂移、免校正、免维护。探头高度的长期稳定性源于高品质材料和元件,实心铂电极及其陶瓷保护层确保测量电池不怕高温粉尘冲击,更不需要多孔陶瓷保护罩,使探头反应更快、数据更精确、使用寿命更长。 |
|
|
|
SGM7型氧量分析仪 |
在许多使用保护气和混合气条件下的工艺过程中,微氧的存在有损于产品品质。运用SGM7型氧量分析仪可以快递和精确测定微氧含量,使工艺过程达到******状态。其主要应用领域是焊接技术生产工艺过程中的监控功能(例如保护气控制下的回流焊接)。 |
|
|
|
ZR5型氧量分析仪 |
ZR5型测氧仪的核心技术是齐洛克斯所研发的ZrO2固体电解质技术,用于连续检测工业气体和保护气体中的含氧量,确保特定的生产工艺处于保护气控制之下,保护气的纯度得到有效监视。 |
|
|
|
EC微型氧量分析仪 |
该分析仪内置有一款新开发的电化学测量电池,非常值得推荐。其一,它特别适用于某些要求低能耗、低成本的工艺过程;其二,由于在某些工艺过程中存在碳氢化合物,因而不适用氧化锆电池测量,此时,选择EC微型氧分析仪不失为上策。 |
|
|
|
|
|
|
|
|
|
Oxygen Measuring Module ZR5 |
For continuous measurements in industry equipments, laboratory gas supplies and for the monitoring of protective gases
|
|
|
|
|
|
Measuring Cells |
Customized zirconia cells
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
QE-Probe
Probe Electronic
Electronic Unit E2001
General Information
The electronic unit E2001 is the basic device for the using of ZIROX® oxygen probes. The signals of ZIROX® probes will be recorded with the E2001, processed to the oxygen concentration according to the NERNST equation and given out by standard interface (4-20 mA). Via E2001 the power supply and the heating control will be realized for heated ZIROX® probes.
Features
- Signal processing and measuring value display for ZIROX® probes
- Measuring value output via standard interface
- Power supply and heating control for heated ZIROX® probes
Data sheet
|
|
|
|
|
|
|
|
|
|
|
|
|
High-Precision Oxygen measuring Device SGM5
General Information
The compact high-precision measuring device SGM5T contains the approved calibration- and drift-free ZIROX® zirconia measuring cell as well the process electronic (for cell heating control, flow monitoring, cell signal processing, calculations and signal output, e.g. oxygen concentration, air factor , redox-quotient or H2O/H2-Ratio) A microprocessor changes the cell signal to the oxygen concentration according the NERNST equation. The value will be shown at the display and output as analog current signal (Option: digital interface RS232, software for measuring value recording and storage is deliverable) Additionally the electronic can process and output the signals of a further, optional integrable sensor (e.g. CO2-, humidity- or pressure sensor with standard interface).
In the SGM5 the measuring cell will be monitored simultaneously. In the case of error a alarm signal will be generated.
Applications
In many technological processes under protective or inert gases oxygen traces are nonconstructively for the product properties. Precondition for detection and prevention of problems is the fast and precious measurement of oxygen respectively the determination of the reducing force of inert gases. By progressive introduction of quality assurance systems, e.g. according to ISO 9000, a constant monitoring and documentation of quality parameters becomes more important. For it with the SGM5T the user get several possibilities for process optimization (soldering and welding processes, heat treatment of metallic surfaces, microelectronic production, food packing technology). For the monitoring of reducing gases further parameters (redox-quotient, air factor , H2O/H2-Ratio or CO2/CO-Ratio) can be calculated by special mathematical methods.
Data sheet
|
|
|
|
|
|
|
|