Ventil designs, manufactures and delivers valve test units for pressure testing any type of Gate-, Globe-, Plug-, Ball-, Check-, Slide- and Butterfly valve according to all international test standards.
Capabilities
√ Range DN10 – 2200 mm. / ¼ - 86”
√ Horizontal (stem vertical), vertical (stem horizontal) or tilting clamping system.
√ Clamping on the inlet flange, both flanges or (proportional clamping) between the clamping tables.
√ 1 – 2000 ton’s of clamping force.
√ With no or limited linear force on the valve body.
√ Test pressure range: from vacuum up to 2000 bar / 30,000 PSI.
√ Test medium: Liquid, compressed air, Nitrogen, Helium or Hydrogen.
Optional features
√ Computer registration system.
√ Full automatic operation system.
√ Testing one or a complete series of valves.
√ Automatic open close action.
√ Valve performance testing, considering; measuring of the stroke measuring,
open/close time and torque measuring.
√ Fugitive emission and cryogenic test facility’s.
|
VCB-25 1/2-10"
VCB-50 1/2-16"
VCB-100 2-24"
HC-100 4-24"
HC-250 4-24"
HC-600 4-36"
Butterfly valve tester |