德国Waycon编码器
Encoder and Transducer
We have over 80 different shaft encoders in our programm. The following transducers are only a small range of our encoder programm. Ask for additional information for our heavy industry transducers and our tacho sensors.
德国Waycon显示控制
应用领域:
收集测量数据
可视化
质量管理
工业
生产定制机
产品介绍:
Display Control
Built-in Multifunctional Meters for visualisation of position. The possibility to calibrate over 36 steps enables customised inearisations. Analogue outputs and switching outputs (comparator) are available. The meter can be connected easily to a PC.
|
|
|
|
Product |
WAY-AS |
WAY-DS |
LT10A/LT11A/LT20A/ LT30 |
Display axes |
2 (one can be seen) |
2 |
1 and 2 |
Input analog |
0...10V, 4...20mA |
|
|
Input digital |
|
HTL |
DT/DT5/DG/DK |
Sensor supply |
yes until 50mA |
yes until 50mA |
yes |
Digit |
5 |
6 |
7 |
Output |
optional |
optional |
yes |
RS232 |
|
optional |
optional or BCD |
Sensor typ |
Draw wire, LVDT, Magnetostrictive, Ultrasonic, Eddy current, Rotary sensor |
Draw wire, Encoder, |
Digital ruler |
More information |
|
|
|
|
|
|
|
Product |
LG |
LH |
LY71/72 |
Display axes |
1,2,3 |
1,2,3 |
3 |
Input anlaog |
|
|
|
Input digital |
SJ300, SJ700, GBER, PL20C |
SJ300, SJ700, GBER, PL20C |
SJ300, SJ700, GBER, PL20C |
Sensor supply |
yes |
yes |
yes |
Digits |
7 |
7 |
|
Output |
|
|
|
RS232 |
|
|
BCD/RS232 |
Sensor typ |
Digital ruler, Magnetical scale |
Digital ruler, Magnetic scale |
Digital ruler, Magnetic scale |
More information |
|
|
|
|
|
|
|
Product |
PAXI |
PAXP / DP |
PAXD |
Display axes |
1 |
1 / 2 |
1 |
Input analog |
|
0...10V, 4...20mA/ 2 x 0...10V, 4...20mA |
Potentiometer |
Input digital |
TTL, THL |
|
|
Sensor supply |
yes until 50mA |
yes until 50mA |
yes until 50mA |
Digits |
6 |
5 |
5 |
Output |
optional |
optional |
optional |
RS232 |
optional |
optional |
optional |
Sensor typ |
Draw wire, Encoder, |
Draw wire, Linearpotentiometer / Draw wire, LVDT, Magnetic scale, Ultasonic, Eddy current, Rotary sensor |
Draw wire, Linearpotentiometer/ LVDT, Magnetic scale, Ultrasonic, Eddy current, Rotary sensor |
More information |
|
|
|
德国Waycon超声波传感器
应用领域:
液位测量
医疗系统
控制皮带张力或凹陷
防止碰撞
栈的高度监测
在机器人手爪感知对象
颗粒水平的注塑机
产品介绍:
Ultrasonic
Ultrasonic distance sensors are working contactless and can still detect small objects (e.g. wire Æ 1 mm) at considerable distances. They are able to disregard disturbing backgrounds and functions in fog, dust , dirt or extreme lighting is possible. No correction factors have to be applied and colour does not matter.
|
|
|
|
Product |
UN500, UN1000, UN2500, UN5000 |
UFA1003/UFA1503 |
UFA200, UFA150FB, UFA150CP |
Range |
80...500, 135...1000, 250...2500, 400...5000 |
180...1000mm/180...1000mm |
0...150,20...150, 20...200mm |
Resolution |
0.2%FS, 0.1%FS |
2mm |
0,3mm |
Accuracy max. |
±0,5%FS |
±1%FS |
1%FS |
Protection class |
IP67 |
IP67 |
IP67 |
Output |
0...10V, 4...20mA, switching output |
0...10V, 4...20mA, switching output |
0...10V, 4...20mA, switched output |
Detection bean ø |
200, 300, 500, 100mm |
110mm |
<20mm, <35mm |
Frame form |
41x60x38, BxHxT |
M18x1 |
M12x1 |
More information |
|
|
|
|
|
|
|
Product |
Ux micro 150, Ux micro 500 |
UBA-A-30, UBA-A-40 |
|
Range |
60...170, 120...500mm |
Bahnlaufregelung |
|
Resolution |
<0,5mm |
0,1mm, 0,15mm |
|
Accuracy max. |
1%FS |
±1%FS, ±2%FS |
|
Protection class |
IP67 |
IP67 |
|
Output |
switched output |
0...10V |
|
Detection bean ø |
8mm, 13mm |
±4mm, ±6,5mm |
|
Frame form |
30x46x400, wxhxd, mit M18x1 |
30x74x65, 39x92x80 wxhxd |
|
Information |
|
|
德国Waycon磁致伸缩传感器
应用领域:
气动和液压缸
汽车行业
塑料工业
包装行业
木材工业
印刷机
输送
纺织行业
产品介绍:
Magnetostrictive
An elastic deformability of a wave guide is generated by overlayed magnetical fields. The transit time of the mechanical pulse is proportional to the distance between signal conditioning unit and permanent magnet. It is a contactless and absolute measuring principle.
|
|
|
|
Product |
MAB |
MAZ |
MSB |
Range |
100-4000mm |
100-4000mm |
100-4000mm |
Resolution |
2µm, 5µm, 10µm |
2µm, 5µm, 10µm |
10µm |
Measured value |
position/speed |
position/speed |
position |
Accuracy |
0,02% |
0,02% |
0,02% |
Speed |
< 10 m/s |
< 10 m/s |
< 10 m/s |
Analog output |
0-10 V, ±10 V, ±5 V, 4-20 mA, 0-20 mA |
0-10 V, 0-20 mA, 4-20 mA, (invertiert) |
0,1 -10,1 V, 0,1 -5,1 V, 4-20 mA |
Digital output |
Start/Stop, PWM, SSI, Profibus, CANopen |
SSI, Profibus, CANopen |
start/stop |
Voltage rating |
24 V±20% |
24 V±20% |
18 – 30 V |
Power input |
100 mA |
100 mA |
40 mA |
Protection class |
IP67 |
IP67 |
IP67 |
Operating temperatur |
-30°C..+75°C |
-30°C..+75°C |
-30°C..+90°C |
Operating pressure |
|
until 350 Bar |
until 700 Bar |
Magnet |
silding cursor or floating magnet |
swimmer, open ring, closed ring |
open ring, closed ring |
More information |
|
|
|
|
|
|
Product |
WP Analog Rotary Sensor |
A36, A58 Incremental Encoder |
Sendix Absolut -Encoder |
Output |
0...10V, 4...20mA, Potentiometer |
TTL, HTL, A/A*, B/B*, Z/Z* |
CAN, SSI, Profibus, Interbus |
More information |
|
|
|
德国Waycon线性电位器
应用领域:
气动和液压缸
注射成型机
塑料工业
金属加工
自动化
折弯机
包装机
纺织行业
产品介绍:
Linear Potentiometer
Linear potentiometer are well known displacement transducers. The working principle is a voltage division on a hybride conductive film. It is possible to get different housing and mounting types, like versions for hydraulic cylinders with spherical, clamping jaw mounting or sprung loaded. The first linear potentiometer with a protection class of IP 68 and contactless measurement systems. The LMI- series constitutes a new generation of L. P. A ring magnet leads the transducer contactless in the inside of the sensor. Therefore a cyclenumber of over 100 Mio. is avieable without problems. Against traditional systems this series mutes additional vibrations over the contactless ring magnet. A well designed and inexpensive measurement system that will be established in the market very quickly.
|
|
|
|
Product |
LRW |
LZW |
LMI/LMI12/LME |
Typ |
Rectangular case with rod |
Cylindrical profil brackets |
Cylindrical profile with magnetic drag |
Range |
0...50mm, bis 0...900 mm |
0...50mm, bis 0...750 mm |
0...50mm, bis 0...1000 mm |
Linearity |
±0,05% MB |
±0,05% MB |
±0,05% MB bis ±0,35% MB |
Protection class |
IP60 / IP65 / IP67 |
IP65 / IP67 |
IP67 (LME) / IP68 (LMI / LMI12) |
Displacement force |
≤ 3,5 N (IP60) / ≤ 25 N (IP65) |
≤ 10 N (IP65) / ≤ 30 N (IP67) |
0,5 N |
Operating temeperatur |
-30°C..+100°C |
-30°C..+100°C |
-30°C..+100°C |
Material |
Aluminium housing/stainless steel rod |
Aluminium housing/stainless steel rod |
Aluminium (LME) / steel (LMI / LMI12) |
More information |
|
|
|
|
|
|
|
Product |
LRW1 |
LZW1 |
LSW |
Typ |
Rectangular case with a double rod |
Cylindrical profil
bracket/bearing/flanges |
Rectangular case sledge typ |
Range |
25 – 150 mm |
25 – 250 mm |
100 – 2000 mm |
Linearity |
±0,2% MB bis ±0,05% MB |
±0,2% MB bis ±0,05% MB |
±0,05% MB |
Protection class |
IP40 |
IP60 |
IP40 |
Displacement force |
≤ 0,3 N |
≤ 0,5 N |
≤ 1,2 N |
Operating temeperatur |
-30°C..+100°C |
-30°C..+100°C |
-30°C..+100°C |
Material |
Aluminium (housing) / steel (rod) |
Aluminium (housing) / steel (rod) |
Aluminium (housing) |
More information |
|
|
|
|
|
|
|
Product |
LRW2, LRW3 |
LZW2 |
PMU/PMI |
Typ |
Rectangular case return spring |
Cylindrical profil
bracket/bearing/flanges |
potentional transducer |
Range |
10 – 150 mm |
25 – 300 mm |
converts potentiometersignals in 0...10 V or 4...20 mA |
Linearity |
±0,3% MB bis ±0,05% MB |
±0,2% MB bis ±0,05% MB |
Input: 1...10 kOhm |
Protection class |
IP40 |
IP60 |
IP40 |
Displacement force |
≤ 4 N |
≤ 0,5 N |
/ |
Operating temperatur |
-30°C..+100°C |
-30°C..+100°C |
-40...+85°C |
Material |
Aluminium (housing) / steel (rod) |
Aluminium (housing) / steel (rod) |
plastic |
More information |
|
|
|
德国Waycon数字磁秤
应用领域:
精密机床
数控/数控车床,铣床
木工机械
激光切割机
位置控制布局设计机
直线电机的速度控制及气瓶
检测仪器
注塑机
产品介绍:
Digital Magnetic Scale
The digital magnetic scale ® consits of a band-shaped magnetic and a reading head with the from Sony® developed MR-Element, which even by little changes of the magnetic flux a stron and stable output signal is generated. The output signal of the reading head, is electronicay divided and converted into a digital signal. This has a much higher resolution as the pole divider of the magnetised, magnetic alternating field and therefore it can be used to measure and control.
Brandname change from „Sony“ to „Magnescale“
After the 1st of April 2010, the logo on the products, manuals and packages for Digital Magnetic Scale from Sony will be replaced to the brandname “Magnescale“. There will be no changes in performance, specifications and quality of the products. In the transfer phase of 2010, it might be possible that the customers receive products with the name Sony and Magnescale.
|
|
|
|
Product |
SJ-700A |
GB-ER |
Sr-33 |
Range |
150-16000mm |
50-2200mm |
70-2040mm |
Accuracy |
± 10µm |
± 5µm |
± 3µm |
Resolution |
5µm |
± 0,5µm |
0,05µm |
Protection |
IP54 |
IP54 |
IP54 |
Hight |
53,6mm |
42mm |
57,9mm |
Output |
A/B visual |
A/B visual |
1 Vss, with referenzpoint |
Datasheet |
|
|
|
|
|
|
|
Product |
SL-110/130 |
Display |
|
Range |
100-300000mm |
1-3 axes |
|
Accuracy |
from ± 25µm |
seven digits |
|
Resolution |
10 µm |
/ |
|
Protection |
IP 6754 |
standard |
|
Height |
39 mm |
/ |
|
Output |
TTL Linedriver A/A*, B/B* |
visual |
|
Datasheet |
|
|
德国Waycon数字压力表
Digital Gauge
The digital gauges from Sony® are high-presicion measurement instruments with a resolution up to 0.1 µm. They work after the mature sony-magnescale-principal and delivers a incremantal output signal. For the direct connection to the SPS or to a positional display, these are the ideal instruments for the automated assembly. A special recording head garanties the extreme pitch accuracy. The more-column reading head generated out of the magnetized example on the gauge corresponding signal. The generated analog signal from the reading head, is electronically divided and digitized.
br>
Brandname change from „Sony“ to „Magnescale“
After the 1st of April 2010, the logo on the products, manuals and packages for Digital Gauges from Sony will be replaced to the brandname “Magnescale“. There will be no changes in performance, specifications and quality of the products. In the transfer phase of 2010, it might be possible that the customers receive products with the name Sony and Magnescale.
|
|
|
|
Product |
DT12, DT32 |
DT512 |
DK802/DK812 |
Range (L) |
12mm, 32mm |
12mm |
2, 12mm |
Resolution |
5µm |
1µm |
0.1µm, 0.5µm |
Accuracy max. |
±5µm |
±3µm |
±0.5µm, ±0.75µm |
Output |
A/A*, B/B* with MT |
|
A/A*, B/B*, Z |
Connetion form |
TTL linedriver (RS422) mit MT |
|
TTL Linedriver (RS422) |
Voltage rating |
+5DC ±5% |
|
+5DC ±5% |
Protection class |
max. IP64 |
max. IP64 |
IP66 |
Referenz point |
|
|
yes |
More information |
|
|
|
|
|
|
|
Product |
DK10/25/50/100/155/205mm |
DG-Series |
DL310B/DL330B |
Range (L) |
10, 25, 50, 100, 155, 205mm |
5-205mm |
10mm/0.39 30mm/1.18 |
Resolution |
0,5µm |
0,5µm |
10µm |
Accuracy max. |
±2µm bis ±6µm |
0,5µm |
±5µm |
Output |
A/A*, B/B*, Z |
A/A*, B/B* only typ M/E |
A/B |
Connection form |
TTL linedriver (RS422) |
TTL linedriver (RS422) only typ M/E |
A/B phase bei NPN open collector |
Voltage rating |
+5DC ±5% |
+5DC ±5% or 24VDC |
5VDC ±5% |
Protection class |
max. IP64 |
max. IP64 |
IP64 |
Referenz point |
yes |
|
|
Display LT-Series |
LT30, LH, LY |
LT20 |
LTA |
More information |
|
|
|
|
|
|
|
Product |
MG-10/20/30 Multi point measuring device |
MG-40 series Multi point measuring device |
|
Range |
up to 64 digital gauges |
up to 100 digital gauges |
|
Resolution |
modular assembly |
modular assembly |
|
Accuracy max. |
/ |
/ |
|
Output |
RS-232C, BCD |
Ethernet |
|
Connection form |
38400 BPSS |
10 mbps data transfer |
|
Voltage rating |
11-26,4VDC |
11-26,4VDC |
|
Information |
|
|
|
Important information!
- &wrap= | &md5=b32f5995637ac2421c06aa5a5817ff42','cb543688d93d8a74791d14e2744a55e4','width=800,height=464,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/MT12_MT13_MT14_Messtaster_Detektor_01.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=b32f5995637ac2421c06aa5a 5817ff42" target=thePicture> - MT12/13/14
DL10BR/DL30BR replaced through DT12 + MT12/13/14
DL60BR replaced through the DK series.
德国Waycon数字标尺
应用领域:
精密机床
数控/数控车床,铣床
木工机械
激光切割机
位置控制布局设计机
直线电机的速度控制及气瓶
检测仪器
注塑机
产品介绍:
Digital Ruler
The digital rulers from Sony® have a reading head with a flexible swivel guide and are ideal for the mounting on multisystems for
example: milling- and turning machines or roboter equipment. The positional displays contain all the necessary programm functions
for the businesses of tool machinerys. A special recording head garanties the extrem accuracy pitch. The multiple reading head
generates an adequate signal from the magnetised example of the digital ruler. The generated analog signal from the reading head
is divided electronically and digitized. (product video SJ300)
Brandname change from „Sony“ to „Magnescale“
After the 1st of April 2010, the logo on the products, manuals and packages for Lasercale from Sony will be replaced to the brandname “Magnescale“. There will be no changes in performance, specifications and quality of the products. In the transfer phase of 2010, it might be possible that the customers receive products with the name Sony and Magnescale.
|
|
|
|
Product |
PL20C |
PL81/82 Serie |
PL25 with MJ100/110 |
Typ Digital ruler |
SL110/130 |
SL110/130 |
SL110/130 |
Range |
200-30000mm |
200-30000mm |
200-30000mm |
Resolution |
10μm |
10, 20, 25, 50, 100μm, adjustable |
5, 10, 25, 50, 125μm, adjustable |
Displacement speed |
300m/min |
300m/min |
300m/min |
Output |
A/A*, B/B* |
A/A*, B/B* |
A/A*, B/B* |
Connetion form |
TTL linedriver (RS422) |
TTL linedriver (RS422), HTL open collector |
TTL linedriver (RS422), HTL |
Voltage rating |
+5DC ±5% |
+5DC ±5%, 10...30VDC |
+5DC ±5% |
Protection class |
IP65 |
IP67 |
IP65 |
Referenz point |
|
|
SETP16 external |
Display LG,
LH70/71/72, LY71 |
yes |
yes |
|
More information |
|
|
|
|
|
|
|
Product |
PL60 with MJ100/110 |
PL101, PL101 with MJ620 |
Digital Display |
Typ Digital ruler |
SL331 |
SL700 Series |
1...3 axes |
Range |
200-8000mm |
50-30000mm |
50-30000mm |
Resolution |
2, 4, 5, 10, 20, 50μm, adjustable |
1μm |
7-digit display |
Displacement speed |
250m/min |
6,4m/s, 24m/s |
access: PL20C |
Output |
A/A*, B/B* |
Sin, Cos, A/A*, B/B*,Z |
SJ700A, GB-ER, SJ300 |
Connection form |
TTL linedriver (RS422), HTL |
1Vss, TTL linedriver (RS422) |
optional mit BCD, RS232 |
Voltage rating |
+5DC ±5% |
+5DC ±5% |
|
Protection class |
IP65 |
IP67 |
|
Referenz point |
SETP16 external |
yes |
|
Display LG,
LH70/71/72, LY71 |
yes |
|
|
More information |
|
|
|
德国Waycon激光传感器
应用领域:
厚度测量轧制轧制品
定心轮轴
四轮定位
自动化
质量控制
过程监控
化学工业
专用机械
产品介绍:
Laser
Laser Distance Sensors are based on the high precise triangulation principle. Due to the intelligent signal analysis, it permits fast and easy measuring of static as well as dynamic moving targets.
|
|
|
|
Product |
LAS-TM, LAS-Z, LAS-T |
LAM |
LLD |
Range |
16, 104mm(TM); 20, 100, 120, 200, 400, 800mm (Z); 40, 250, 500, 800mm (T) |
0,5, 2, 10, 20, 50, 100, 200, 400mm |
0,1...150m adjustable |
Resolution |
2µm |
0,2µm |
0,1mm |
Accuracy max. |
±6µm |
±1µm |
±3mm, recurence ±0,5mm |
Reaction time |
100Hz, 1kHz (T, TM) |
10kHz, 37kHz |
10Hz, 50Hz |
Output |
0...10V, 4...20mA, RS485 |
±10V, 4...20mA, 0...10V, RS232C |
4...20mA, RS232C, RS422, Profibus |
Activity |
120mA |
ca. 200mA |
ca. 500mA |
Protection class |
IP67 |
IP64 (Sensor), IP40 Elektronic |
IP54 |
Digital display |
PAXP, WAY-AS |
PAXP, WAY-AS |
PAXP, WAY-AS |
Data information |
|
|
|
Manual |
|
|
|
Software |
|
|
link is after the chart |
|
|
|
|
Product |
LSCAN, 2 axes Z/X |
PAXP Digital display |
LLD-Communication & data acquisition |
Range |
10/13, 15/10, 17/10, 40/20, 60/30, 85/46, 120/54, 120/54, 200/68, 220/120, 1200/600mm |
5-digit display |
Softwareversion V1.0.1 |
Resolution |
0,02mm |
analog input 0...10V, 4...20mA |
communication & data collection |
Accuracy max. |
±0,2 % MB |
limit values |
parameterisation, scaling |
Reaction time |
50 oder 100 Hz |
output: USB, RS232, profibus |
data file, graphic, display |
Activity input |
450mA |
|
|
Protection class |
IP64 |
|
|
More information |
|
|
|
Software LLD Laser (80 MB) WayCon_LLD_Installer.
rar
德国Waycon涡流传感器
Eddy Current涡流传感器
Since the year 2000, WayCon is engaged in the development and production of eddy current sensors. A wide field of application is generated by the TX series, which was developped in particular for high-end automation and robotics. Our engineers continuously adapt and develop the eddy current sensors further to your special needs.
The eddy current sensors are small useful assistants if it is a matter of measuring distances on metallic objects extremely high-resolution till the nanometer area without touch and freely of wear. The high frequency lines of flux responsible for the measuring principle of the sensors pass non-metallic media unhindered. This quality admits a measurement under oleograph or hydraulic pressure or under strong soiling. Also case parts and materials of plastic can be filled and behind it recumbent metallic objects be grasped. Varnish and foils can be examined for layer strength.
|
|
|
|
Product |
TX |
IC |
CMSS |
Range |
0,5 - 10,00 mm |
0 - 8mm |
0,254 - 7,620 mm |
Linearity |
+/- 0,25 % v. MB |
± 60 µm |
± 50,8 µm |
Resolution |
0,1 µm |
1 µm |
200mV/25,4 µm |
Dynamic |
35 kHz |
1mm/ms |
10 kHz |
Protection class |
67 u 68 |
67 |
65 u 68 |
Output |
analog |
analog |
analog |
More information |
|
|
|
- &wrap= | &md5=300ffb6dbab4bcd1d4e6b4c29696037e','b60713a283779601ceaaaefd40db5004','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/eddy_current_principle.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=300ffb6dbab4bcd1d4e6b4c2 9696037e" target=thePicture>
Welcome to the world of eddy current
The basic measuring principle of the eddy current sensors is based on the fact that the coil generates a magnetic alternating field in the sensor head whose lines of flux leave from the sensor head which pass object, and shut again. Besides, the measuring field (magnetic alternating field) in the electrically leading-capable object generates the eddy current which entail joule losses. These eddy current losses in the object increase with lower distance. On the input side of the electronics the eddy current losses about the change of the impedance are evaluated. A output signal proportional to distance is formed as for example 0... 10 V or 4... 20 mA.
- &wrap= | &md5=486ebe6c2fb9ca563a045090bc05b77e','70a0e61460c2856a2c28de940e1b5da5','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/antriebswelle_wirbelstrom_01.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=486ebe6c2fb9ca563a045090 bc05b77e" target=thePicture>
Main operational area
Main operational area of the eddy current sensors is the check of rotating shafts on imbalance, vibration, unroudness as well as radial and axial runout. For the radial measurement a level coat surface is optimum. Here the relative movement can be measured with a sensor between sensor and shaft.
Arranging two sensors in 90 ° corner, one gets differentiated explanation about unroudness and radial runout.
- &wrap= | &md5=939373f7a1bbd7d05fac86fedf7e82fb','205a5a5ace665fec70f9585ccbbca699','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/differentialrad_wirbelstrom_02.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=939373f7a1bbd7d05fac86fe df7e82fb" target=thePicture>
Gear wheel check
For structured surfaces, as for example with gear wheels or groove shafts, we offer the possibility to fade out either the tooth flank by means of software and to spend the average and to receive therefore information about the radial movement, or to grasp the tooth flanks individually in the maximum values. Here explanation can be received over broken out teeth or shovels or wear.
For example, an investigation of the shaft deflection or radial and axial misalignment can be carried out in the vehicle gear with different load states in the test bench or in the driving attempt. Case distortions can be measured.
- &wrap= | &md5=c2f631681db991881127eacb4f395834','320cddb62096787bd0e485eb1d8cc1ba','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/wellenvibration_wirbelstrom_01.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=c2f631681db991881127eacb 4f395834" target=thePicture>
Machine observation - monitoring
With constantly pursued machines, as for example with turbo-generators in power stations, the state of the bearrings can be supervised. Vibrations beyond the specified area are recognised and the machine can be brought in a reliable operational state, before it comes to cost-intensive and time-luxurious damages.
Furthermore a wear measurement of the main shaft is possible and a servicing interval can be included in the maintenance plan. The behaviour of the rotor can be examined under different load states or with different oleograph in the lubrication gap of the bearrings.
- &wrap= | &md5=3bd2727f869767530949fba65fd2edcc','2e5b6f9baf18805ca0214c4bd658c79c','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/Wirbelstrom_T10_01.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=3bd2727f869767530949fba6 5fd2edcc" target=thePicture>
Construction features
The new WayCon-eddy current sensor T10 with 10 mm of measuring range offers sensible detailed solutions for the connection.
The sensor can be twisted about a standard-key width SW24. For radial inaccessible situations in thread canals the sensor can be mounted by cylinder drillings and a wide groove without damaging the cable.
- &wrap= | &md5=3b1d23a80c30ebde98facd8252942907','3c29963db2971c8217900c78ed8f8ade','width=740,height=575,status=0,menubar=0'); return false;" href="http://www.waycon.biz/index.php?eID=tx_cms_showpic&file=uploads/pics/Wirbelstrom_TFT_Display_02.jpg&width=800m&height=600m&bodyTag=
&wrap= | &md5=3b1d23a80c30ebde98facd82 52942907" target=thePicture>
TFT-touch-screen – Soon available
Only short time, then the devices of the TX series with TFT-Touch-Screen are available. The generous display offers many interesting possibilities as for example
- Display of measuring value with the highest resolution
- Adjusting and observing of limit values
- Teach and scaling the displayed value / analog output
- Cash graph with visualisation of the borders
- Graph for rotary shafts with picture of 360°
- Customised linearisation
Currently bought devices can be postprepared any time. Ask us for it...
德国Waycon 拉线传感器 线性可变差分变压器(LVDT)
Draw Wires拉线传感器
Draw wire sensors are suitable for measuring linear and non-linear motions. The compact style allows flexible and easy installation. Due to the small size, precise measurement is possible even in difficult applications. (Product video)
|
|
|
|
Product |
Series SX50/ SX80/SX120 |
SX135 |
Hydraulic transducer SX300 |
Range |
von 0-50...1250mm, 0-2000...3000mm, 0-3125...6000mm |
0-8000mm, 0-10... 11, 12, 15, 20, 25, 30, 40m |
0-1m...15m |
Measured value |
position |
position |
position |
Accuracy max. |
±0,01% |
±0,01% |
±0,05% |
Output analog |
0...10 V, 4...20mA, Potentiometer |
0...10 V, 4...20mA, Potentiometer |
- |
Output digital |
TTL, HTL, SSI, Profibus, CANopen, Interbus |
TTL, HTL, SSI, Profibus, CANopen, Interbus |
TTL, HTL, SSI, Profibus, CANopen, Interbus |
Protection class |
IP65 (IP67) |
IP65 (IP67) |
IP65 (IP67) |
Operating pressure |
/ |
/ |
until 300bar |
More information |
|
|
|
|
|
|
|
Product |
Miniatursensor LX |
HX with speed output |
Display PAX I,P,D |
Range |
0-50...1250mm |
0-100...50.000 mm |
incremental HTL |
Measured value |
position |
position/speed |
analog 0...10V, 4...20mA |
Accuracy max. |
±0,1% |
±0,1 |
and potentiometer |
Output analog |
1Rk Potentiometer |
0...10 V, 4...20mA, Potentiometer |
Limit values, sensor supply, RS232 |
Output digital |
TTL |
TTL, HTL |
/ |
Protection class |
IP00 |
IP68 |
Sensor supply, 24VDC, 230V |
Operating pressure |
/ |
/ |
/ |
More information |
|
|
|
Linear Variable Differential Transformers (LVDT)
线性可变差分变送器(LVDT)
Linear Variable Differential Transformers (LVDT) are ideal for applications in harsh industrial environments such as high temperature and pressure applications, dynamic applications and long term cycles.
|
|
|
|
Product |
SL |
SM |
SM-HYD |
Range |
0-50...500mm |
0-2...200mm |
0-10...300mm max. 600mm |
Construction |
rod end bearing, only push rod guided, push rod extricable |
only push rod guided, push rod extricable |
push rod guided |
Accuracy max. |
±0,3%, optional ±0,2% |
±0,3%, optional ±0,2% |
±0,3%, optional ±0,2% |
Output analog |
AC, 0...10V, ±5V, ±10V, 0...20mA |
0...10V, ±5V, ±10V, 4...20mA |
0...10V, ±5V, ±10V, 4...20mA |
Voltage rate |
24V (12...36VDC), 15V (12...18VDC) |
24V (12...36VDC), 15V (12...18VDC) |
24V (12...36VDC), 15V (12...18VDC) |
Power input |
from 65 mA |
from 65 mA |
from 65 mA |
Protection class |
IP65 optional IP68 |
IP65 optional IP68 |
IP65 optional IP68 |
Operating temperatur |
-40°C..+120°C, +150°C (only sensor) |
-40°C..+120°C, +150°C (only sensor) |
-40°C..+120°C, +150°C (nur Sensor) |
Operating pressure |
- |
- |
400 bar |
More information |
|
|
|
|
|
|
|
Product |
SM-F18 ø12mm, Flansch ø18 |
|
|
Range |
0-10...300mm max. 600mm |
|
|
Construction |
rod end bearing |
|
|
Accuracy max. |
±0,3%, mit option ±0,2% |
|
|
Output analog |
AC, 0...10V, ±5V, ±10V, 0...20mA |
|
|
Voltage rate |
24V (12...36VDC), 15V (12...18VDC) |
|
|
Power input |
from 65 mA |
|
|
Protection class |
IP65 bis IP68 |
|
|
Operating temperatur |
-40°C..+120°C, +150°C (only sensor) |
|
|
Operating pressure |
150 bar |
|
|
|
|
德国Waycon位移传感器
|
Draw Wire
- Range 50 - 50000 mm
- Accuracy 0,05% - 0,25%
- Resolution 0,1 - 1 mm
- Output 10V, 4-20mA, A/B/Z, SSI, CAN, Par.
- Measurement through draw wire
|
|
|
Inductive Gauge LVDT
- Range 2 - 600 mm
- Accuracy 0,1% - 0,3%
- Resolution 5 - 200 µm
- Output 5V, 10V, bipolar, 4-20mA
- Measurement through free core, guided or sprung loaded push rod
|
|
|
Eddy Current Probe
- Range 0,5 - 8 mm
- Accuracy 0,25%
- Resolution 100 - 1000 nm
- Output 5V, 10V, bipolar, CAN
- Contactless measurement at metallic objects
|
|
|
Laser
- Range 0,5 - 800 mm
- Accuracy 2 - 2000 µm
- Resolution 1 - 100 µm
- Contactless through triangulation
|
|
|
Digital Magnetic Scale
- Range 50 mm - 50 m
- Accuracy 10 - 100 µm
- Resolution 0,1 - 5 µm
- Output A/B u. Ref., TTL, Vss
- Contactless through magnetic floater
|
|
|
Digital Gauge
- Range 5 - 205 mm
- Accuracy 1 - 10 µm
- Resolution 0,2 - 5 µm
- Output A/B u. Ref., TTL
- Measurement through sprung loaded push rod
|
|
|
Digital Ruler
- Range 15 - 2170 mm
- Accuracy 2 - 10 µm
- Resolution 0,1 - 5 µm
- Output A/B u. Ref., TTL, Vss
- Measurement through reading head
|
|
|
Linear Potentiometer
- Range 10 - 2000 mm
- Accuracy 0,05% - 0,2%
- Resolution k. A.
- Output potentiometrisch
- Measurement through guided/sprung loaded/slider/ring
|
|
|
Magnetostrictive
- Range 50 - 4000 mm
- Accuracy 0,02% - 0,1%
- Resolution 1 - 100 µm
- Output 10V, 4-20mA, Tacho, Start-Stop, PWM, Profibus
- Contactless through floating cursor or ring magnet
|
|
|
Ultrasonic
- Range 100 - 6000 mm
- Accuracy 0,7% - 1,5%
- Resolution 1 - 3 mm
- Output 5V, 10V, 4-20mA
- Contactless through ultrasonic sound reflection
|
|
|
Display + Control
- Multifunctional display
- Input analog/digital
- 1 - 10 channels
- Built in and external units (miller/lathe)
- Distance and velocity, comparator...
|
|
|
Angle Transmitter + Encoder
- Single and multiturn
- Analogue and digital transducer
- Solid shaft/hollow shaft
- Output A/B/Z, CAN, Profibus, 10V, 4-20mA, 1k
- Rotational measurement
|
Inkremental Encoder
|
Absolut Encoder
|
Modular Encoder
|
resolution up to 512.000 pulses/turn
|
temperature: -30...+ 100 °C
|
frequency up to 200 kHz
|
protection class up to IP 65
|
linedriver, push-pull, antivalent
|
hollow shaft versions
|
shaft or syncro flange
|
customised versions
|
encoder for ex-protection
|
|
resolution: 13 bit-singleturn; - 29 multiturn
|
programable code
|
different output versions
|
codes: gray, binary, BCD, excess3
|
selectable code
|
hollow shaft versions
|
shaft or syncro flange
|
customised versions
|
encoder for ex-protection
|
|
resolution: 1024 pulses/turn
|
temperature: -40...+ 100 °C
|
frequency up to 125 kHz
|
linedriver, TTL and CMOS
|
supply: + 5 V
|
shaft diameter: 2...12.7 mm
|
different dimensions
|