德国盖米Gemue传感器系统及显示装置
传感器系统显示单位
压力测量系统
流量测量系统
液位测量系统
温度测量系统
|
|
|
The universal display unit GEMÜ 1275 can be used in the field of machine and plant construction and in laboratory and processing systems. A display of up to 4 1/2-digits shows the various measurement values (pressure, temperature, flow). Versions ZP, ZT and ZF can be programmed via a keyboard at the front.
|
|
|
|
|
Photo
|
Type
|
Description
|
|
GEMÜ 1275
|
Universal digital display unit
3 1/2 or 4 1/2 digit LED display
0-10V; 0/4-20mA input signal
optional relay outputs
|
|
Pressure measurement systems
|
|
|
|
The GEMÜ 3120 is available in various different versions for the pressure measurement system area. The devices are available as pressure transducers, differential pressure transducers and differential pressure measurement devices. Pressure transmitters and pressure measurement devices for the high purity area can be found under HydraLine- pressure measurement system.
|
|
|
|
|
Photo
|
Type
|
Description
|
|
GEMÜ 3120
|
Pressure/differential pressure transmitter
Versions: 2-wire transducer or
4-wire pressure measuring device with display
|
|
|
|
|
GEMÜ offers various function principles for the area of flow measurement systems:
- Flowmeters according to the variable area principle for the measurement ranges from 2-20,000 l/h, suitable for the attachment of limit switches, instrument sensors and reed contacts to detect measurement values and to transmit them.
- Flow transmitters can be used both as pure measurement turbines and as totalizers or batch controllers for measurement ranges from 0.3 – 25,000 l/h. The measurement turbines provide various electrical output signals for further processing.
- A magnetically inductive flowmeter (MID) completes the product range. It can be used for nominal sizes of DN 25 – 300 and be set precisely to the respective application conditions using its electronics. Interfaces such as R232 and Profibus-DP enable uncomplicated integration in fully automated plant control systems.
- SonicLine® ultrasonic flowmeter for corrosive and ultra pure media. The device has no moving parts in the medium flow and has a measuring range from 0.03 – 120 l/min (0.5 – 2000 ml/sec.) depending on the nominal size.
For further information please refer to the product list below and the download area.
|
|
|
|
|
Photo
|
Type
|
Description
|
|
GEMÜ 800
|
Flowmeter
variable area principle.
For inert or corrosive liquids and gases.
Mounting facility for electrical limit switches or instrument sensors.
DN 20 - 65
|
|
GEMÜ 840
|
Flowmeter
part flow principle.
For inert or corrosive liquids.
Mounting facility for electrical limit switches or instrument sensors.
DN 65
|
|
GEMÜ 850
|
Flowmeter
variable area principle
For inert or corrosive liquids and gases.
Mounting facility for electrical limit switches or instrument sensors.
DN 10 - 15
|
|
GEMÜ 1250
|
Limit switch acc. to ATEX
With integrated bistable Reed change-over contact.
For GEMÜ flowmeters with magnetic float.
For GEMÜ 800 flowmeters
|
|
GEMÜ 1251
|
Limit switch max. contact acc. to ATEX
and UL-approval
With integrated bistable Reed contact
For GEMÜ flowmeters with magnetic float.
For GEMÜ 800 flowmeters
|
|
GEMÜ 1252
|
Limit switch min. contact acc. to ATEX
and UL-approval
With integrated bistable Reed contact
For GEMÜ flowmeters with magnetic float.
For GEMÜ 800 flowmeters
|
|
GEMÜ 1256
|
Limit switch max. contact acc. to ATEX
and UL-approval
With integrated bistable Reed contact
For GEMÜ flowmeters with magnetic float.
For GEMÜ 850 flowmeters
|
|
GEMÜ 1257
|
Limit switch min. contact acc. to ATEX
and UL-approval
With integrated bistable Reed contact
For GEMÜ flowmeters with magnetic float.
For GEMÜ 850 flowmeters.
|
|
GEMÜ 1270
|
Instrument sensor acc. to ATEX
For flowmeters with variable area principle.
With integrated chain of resistors.
For GEMÜ 800 flowmeters
|
|
GEMÜ 1271
|
Instrument sensor acc. to ATEX
For flowmeters with variable area principle.
With integrated chain of resistors.
For GEMÜ 850 flowmeters
|
|
GEMÜ 1272
|
Instrument sensor
For flowmeters with variable area principle.
2-wire version with integrated measuring transducer.
For GEMÜ 800 flowmeters.
|
|
GEMÜ 1273
|
Instrument sensor
For flowmeters with variable area principle.
2-wire version with integrated measuring transducer.
For GEMÜ 850 flowmeters.
|
|
GEMÜ 3020
|
Flow transmitter, turbine
For inert, corrosive, liquid aqueous media.
Frequency or current output signal.
DN 25 / 50
|
|
GEMÜ 3021
|
Flow transmitter, turbine
For inert, corrosive, liquid aqueous media.
Totalizer or Batch controller (dosing device),
freely adjustable measuring range.
DN 25 / 50
|
|
GEMÜ 3030 mFlow
|
Magnetically inductive flowmeter
For cost effective measurement of volumetric flow and flow rates.
RS 232 interface, field bus connection.
DN 25 - 300
|
|
GEMÜ C38 SonicLine
|
High Purity PFA ultrasonic flowmeter, for flow measurement, dosing, batch processes, flow rate control from 0.09 - 120 l/min (depending on DN), high accuracy ± 1% of measured value, ultra-fast 250 measured values/sec., good reproducibility of measured values of 0.5%
|
|
Level measurement systems
|
|
|
|
GEMÜ provides a well-balanced product range of level measurement systems for recording measurement values and system automation. The LevelLine line of products which we supply is a compact modular system for the most varied of application areas. As well as various function principles, several attachment and installation variants can be selected. Level controllers in various designs make integration in plant automation easy.
|
Function principles
|
Level switches with a float, ultrasonic (contactless), vibration, capacitance, optical level switches
|
Installation variants
|
Individual installation using unions, clamps or flanges, single point level switch system, multiple level switch system, installation in the stand pipe
|
For further information please refer to the product list below and the download area.
|
|
|
|
|
Photo
|
Type
|
Description
|
|
GEMÜ 902
|
Level transmitter
integrated Reed contacts
for monitoring inert or corrosive media
independent of pressure, conductivity, concentration and density
|
|
GEMÜ 910
|
Level transmitter
integrated chain of resistors
for monitoring inert or corrosive media
independent of pressure, conductivity, concentration and density
|
|
GEMÜ 920
|
Ultrasonic level transmitters
2-wire version
Measuring range 0.15 - 5.4m freely adjustable
|
|
GEMÜ 921
|
Ultrasonic level transmitters
3-wire version
Measuring range 0.15 - 7.4/12.2m freely adjustable
|
|
GEMÜ 922
|
Ultrasonic level transmitters
2-wire version
Measuring range 0.09/0.15 - 1.8/3.7m
|
|
GEMÜ 925
|
Ultrasonic level transmitters
Measuring range 0,15 - 3,7m
Two integrated relay outputs for alarm + filling / emptying function
|
|
GEMÜ 930
|
Level switch - Ultrasonic
with integrated switching output
|
|
GEMÜ 931
|
Level switch - Vibration
with integrated switching output
|
|
GEMÜ 932
|
Level switch - Capacitance
with integrated switching output
|
|
GEMÜ 933
|
Level switch - Float
with integrated switching output
|
|
GEMÜ 934
|
Level switch - Optical
with integrated switching output
|
|
GEMÜ 940
|
Multiple level switch system
for mounting of max. 4 level switches GEMÜ 930-934
|
|
GEMÜ 941
|
Single level switch system
for mounting of one level switch GEMÜ 930-934
|
|
GEMÜ 947
|
Compact system
for direct mounting of
one level switch GEMÜ 930-934
|
|
GEMÜ 1290
|
Level controller
for DIN rail mounting
switching amplifier with alarm or filling / emptying function
|
|
GEMÜ 1291
|
Level controller
for mounting to GEMÜ 930 - 947
as junction box or switching amplifier with alarm or filling / emptying function
|
|
Temperature measurement systems
|
|
|
|
GEMÜ 3220 is available as a temperature transducer and a temperature measurement device with an integrated display. Measurements are made by a PT100 temperature sensor.
|
|
|
|
|
Photo
|
Type
|
Description
|
|
GEMÜ 3220
|
Temperature transducer
Versions: 2-wire transducer or 4-wire temperature measurement device with display
|
|
|