sysmik GmbH通讯模块 EIA709 EIA852 接口/网关 显示设备 电源UPS
德国sysmik GmbH通讯模块 EIA709 EIA852 接口/网关 显示设备 电源UPS
产品系列:
Produkte/Hardware/Infrastrukturkomponenten EIA709 |
|
SmartRouter / EIA-709 |
|
|
LonMark compliant LonWorks router with two network interfaces.
Side-A: TP/FT10 transceiver
Side-B: opional TP/FT10 or TP/XF1250 transceiver (SmartRouters with TP/FT10 transceiver are compatible to LPT*-10 transceivers)
The version RTRSD contains an addtionally diagnostics node for watching networks with loop- or line-topologies.
*) LPT ... Link Power Transceiver
|
|
More... |
|
|
Standard- SmartRepeater / EIA-709 |
|
|
Physical repeaters (RPT) are used for connecting two (RPT-..x2), or three (RPT-..x3) segments of a LONWORKS?network.
SysMik offers repeaters with different cases (Panel-, Wall- and Din-Rail mounting) and with various transceivers (TP/FT10, RS485) and for different power supply voltages. |
|
More... |
|
|
Powerliner Router/ EIA-709 |
|
|
Powerline-Router RTRS-TP/FT10-PL20 >NEW<
Routers are devices to structure networks logically and physically.
The power line routers of the family RTRS TP/FT10 PL20 are
standard LON routers to transmit messages between TP/FT-10
and power line.
Attention product replacement!
The Power Line Router series RTR-TP/FT10-PLT22C is
replaced
by our new generation Powe Line Routers RTRS-TP/FT10-PL20 |
|
More... |
|
|
Data Point Connector XFM-LL / EIA-709 |
|
|
Data point connector for non-reactively connecting data points from different TP/FT10 networks:
- safe separation of unions in complex projects
- Data exchange over domain bounds
- Firewall funktionality
|
|
Mehr... |
|
|
L-Switch xp / EIA-709 |
|
|
A L-Switch xp Multiport-Switch connects serveral bus segments and can forward messages from one port to an other selected by source- and destination addresses.
Remark: The L-Switch xp is made by the Austrian company LOYTEC electronics GmbH.
|
|
More... |
|
|
Bus terminators / EIA-709 |
|
|
Network terminators are containing passive networks for an optimal wiring termination within LonWorks?networks according to the LonMark?Interoperability Guidelines.
Our terminators are conform to the guidelines of the company Echelon?
The required type depends on the selected transceiver type and network topology. |
|
More... |
|
|
|
Order summary of product group |
|
Device name |
Transceiver |
Supply |
Remark |
Part number/Details |
SmartRouter |
RTRS-TP/FT10-TP/FT10 230V AC |
Network-A
TP/FT10 |
Network-B
TP/FT10 |
optional
24V AC/DC
230V AC |
Echelon
RTR10-Core-Module |
1102-100121-05-6 |
RTRS-TP/FT10-TP/FT10 24V AC/DC |
Network-A
TP/FT10 |
Network-B
TP/FT10 |
only
24V AC/DC |
Echelon
RTR10-Core-Module |
1102-100121-06-3 |
RTRS-TP/FT10-TP/XF1250 230V AC |
Network-A
TP/FT10 |
Network-B
TP/XF1250 |
optional
24V AC/DC
230V AC |
Echelon
RTR10-Core-Module |
1102-100121-01-8 |
RTRS-TP/FT10-TP/XF1250 24V AC/DC |
Network-A
TP/FT10 |
Network-B
TP/XF1250 |
only
24V AC/DC |
Echelon
RTR10-Core-Module |
1102-100121-02-5 |
RTRS-TP/FT10-TP/RS485 230V AC |
Network-A
TP/FT10 |
Network-B
TP/RS485 |
optional
24V AC/DC
230V AC |
Echelon
RTR10-Core-Module |
1102-100121-11-7 |
SmartRouter with bus diagnostics |
RTRSD-TP/FT10-TP/FT10 230V AC |
Network-A
TP/FT10 |
Network-B
TP/FT10 |
optional
24V AC/DC
230V AC |
Echelon
RTR10-Core-Module
Bus diagnostics line/loop |
1102-100121-07-0 |
RTRSD-TP/FT10-TP/FT10 24V AC/DC |
Network-A
TP/FT10 |
Network-B
TP/FT10 |
only
24V AC/DC |
Echelon
RTR10-Core-Module
Bus diagnostics line/loop |
1102-100121-08-7 |
RTRSD-TP/FT10-TP/XF1250 230V AC |
Network-A
TP/FT10 |
Network-B
TP/XF1250 |
optional
24V AC/DC
230V AC |
Echelon
RTR10-Core-Module
Bus diagnostics line/loop |
1102-100121-03-2 |
RTRSD-TP/FT10-TP/XF1250 24V AC/DC |
Network-A
TP/FT10 |
Network-B
TP/XF1250 |
only
24V AC/DC |
Echelon
RTR10-Core-Module
Bus diagnostics line/loop |
1102-100121-04-9 |
Device name |
Transceiver |
Supply |
Remark |
Part number/Details |
LOYTEC L-Switch xp |
LS-13300CB |
Network-1
TP/XP1250 |
Network-2..3
TP/FT10 |
nur
24V AC/DC |
LOYTEC
L-Core-Firmware |
1102-100204-01-8 |
LS-13333CB |
Network-1
TP/XP1250 |
Network-2..5
TP/FT10 |
nur
24V AC/DC |
LOYTEC
L-Core-Firmware |
1102-100204-02-5 |
Device name |
Transceiver |
Supply |
Remark |
Part number/Details |
Powerline routers |
RTRS-TP/FT10-PL20C1-LN |
Network-A
TP/FT10 |
Network-B
PL20 (C-band, class 122, L-N couling) |
Wide range
100-240V AC |
Echelon
LonMark router software |
1103-100340-01-0 |
RTRS-TP/FT10-PL20C2-LN |
Network-A
TP/FT10 |
Network-B
PL20 (C-band, class 134, L-N couling) |
Wide range
100-240V AC |
Echelon
LonMark router software |
1103-100340-02-7 |
RTRS-TP/FT10-PL20C1-LE |
Network-A
TP/FT10 |
Network-B
PL20 (C-band, class 122, L-E couling) |
Wide range
100-240V AC |
Echelon
LonMark router software |
1103-100340-03-4 |
RTRS-TP/FT10-PL20A2-LN |
Network-A
TP/FT10 |
Network-B
PL20 (A-band, class 134, L-N couling) |
Wide range
100-240V AC |
Echelon
LonMark router software |
1103-100340-04-1 |
ACC-PC3-400 |
|
|
|
3-phases coupler for powerline routers
V_LN equals 400Vrms |
1104-100133-02-2 |
ACC-PC1 |
|
|
|
Low voltage coupling device
|
1104-100342-01-1 |
Device name |
Transceiver |
Supply |
Remark |
Part number/Details |
SmartRepeater |
RPTS-TP/FT10x2 230V AC |
TP/FT10
|
2 |
optional
24V AC/DC
230V AC |
Putting c-clamp
RJ-45 |
1101-100122-01-8 |
RPTS-TP/FT10x2 24V AC/DC |
TP/FT10
|
2 |
only
24V AC/DC |
Putting c-clamp
RJ-45 |
1101-100122-02-5 |
RPTS-TP/FT10x3 230V AC |
TP/FT10
|
3 |
optional
24V AC/DC
230V AC |
Putting c-clamp
RJ-45 |
1101-100122-05-6 |
RPTS-TP/FT10x3 24V AC/DC |
TP/FT10
|
3 |
only
24V AC/DC |
Putting c-clamp
RJ-45 |
1101-100122-06-3 |
Physical standard repeaters for panel- and wall mounting |
RPT-TP/FT10x2-CC 230V AC |
TP/FT10
|
2 |
only
230V AC |
Spring clamps |
1101-100004-01-7 |
RPT-TP/FT10x2-CC 24V AC/DC |
TP/FT10
|
2 |
only
24V AC/DC |
Spring clamps |
1101-100004-03-1 |
RPT-TP/FT10x2-RJ 230V AC |
TP/FT10
|
2 |
only
230V AC |
RJ-45 |
1101-100004-07-9 |
RPT-TP/FT10x2-RJ 24V AC/DC |
TP/FT10
|
2 |
only
24V AC/DC |
RJ-45 |
1101-100004-08-6 |
RPT-TP/FT10x3-CC 230V AC |
TP/FT10
|
3 |
only
230V AC |
Spring clamps |
1101-100004-02-4 |
RPT-TP/FT10x3-CC 24V AC/DC |
TP/FT10
|
3 |
only
24V AC/DC |
Spring clamps |
1101-100004-04-8 |
RPT-TP/FT10x3-RJ 230V AC |
TP/FT10
|
3 |
only
230V AC |
RJ-45 |
1101-100004-05-5 |
RPT-TP/FT10x3-RJ 24V AC/DC |
TP/FT10
|
3 |
only
24V AC/DC |
RJ-45 |
1101-100004-06-2 |
RPT-RS485x2-RJ 230V AC |
TP/RS485
|
2 |
only
230V AC |
RJ-45 |
1101-100164-03-2 |
RPT-RS485x2-RJ 24V AC/DC |
TP/RS485
|
2 |
only
24V AC/DC |
RJ-45 |
1101-100164-04-9 |
RPT-RS485x2-CC 230V AC |
TP/RS485
|
2 |
only
230V AC |
Spring clamps |
1101-100164-05-6 |
RPT-RS485x2-CC 24V AC/DC |
TP/RS485
|
2 |
only
24V AC/DC |
Spring clamps |
1101-100164-06-3 |
Device name |
Transceiver |
Supply |
Remark |
Part number/Details |
Data points coupler |
XFM-LL |
Network-A
TP/FT10 |
Network-B
TP/FT10 |
only
24V AC/DC |
2 MIP controllers as
application router |
1302-100026-14-0 |
Device name |
Transceiver |
Bus topology |
Usage |
Remark |
Part number/Details |
Terminators |
ACC-BT-TP |
TP/XF1250
TP/XP78
|
Line |
Bus terminator |
|
1104-100002-01-4 |
ACC-BT-FT1 |
TP/FT-10
TP/LPT-10 |
Free topology |
Bus terminator |
once 52,5Ohm |
1104-100002-02-1 |
ACC-BT-FT2 |
TP/FT10
TP/LPT-10 |
Line |
Bus terminator |
twice 105Ohm |
1104-100002-03-8 |
|
Products/Hardware/Infra-Structure Components EIA852 |
|
IP-Router / EIA-852 |
|
|
An L-IP-Router connects EIA-709 medias (TP/XF1250 / TP/FT10) to an IP-channel (LonMark IP-852 / Ethernet).
Works as self-learning switch, repeater or configured router to separate data traffic.
|
|
More... |
|
|
Ethernet Hub/Switch |
|
|
Ethernet-Hubs and -Switches
The topology of an Ethernet IP network is different than that of TP/FT-10: For 10/100Base-T there are exclusively point-to-point connections at physical layer. If more than 2 devices shall communicate with each other, switches are recommended. Hubs, as multi port repeaters, have technical disadvantages compared to switches:
- Hubs ... transmit and und regenerate data packets
- Switches ... connecting 10MBit/s- resp.100MBit/s segments / channeling of network traffic / reducing of bus load |
|
More... |
|
|
|
Order summary of product group |
|
Device name |
Transceiver |
Supply |
Part number/Details |
LOYTEC L-IP routers |
LIP-3ECTB |
Network-A
TP/FT10 |
Network-B
100BaseT |
only
24V AC/DC |
1107-100203-03-0 |
LIP-1ECTB |
Network-A
TP/XF1250 |
Network-B
100BaseT |
only
24V AC/DC |
1107-100203-04-7 |
LIP-33ECTB |
Network-A
2xTP/FT10 |
Network-B
100BaseT |
only
24V AC/DC |
1107-100203-05-4 |
|
|
|
Order summary |
Devices |
Description |
RJ45-TP |
FO |
WxHxD mm (inch) |
Part number/Details |
FL Switch SF - Low profile with high port density |
FL SWITCH SF 8TX |
Unmananged switch, alarm contact for redundant power supply, operation range 0(32) - 55(131) Grad Celsius (Fahrenheit) |
8 |
0 |
135x94,3x30 |
2832771 |
FL SWITCH SF 14TX/2FX |
s.a. |
14 |
2 |
205x115,3x30 |
2832593 |
FL SWITCH SF 15TX/FX |
s.a. |
15 |
1 |
205x115.3x30 |
2832661 |
FL SWITCH SF 16TX |
s.o. |
16 |
0 |
205x94,3x30 |
2832849 |
|
|
Order summary |
Devices |
Description |
RJ45-TP |
FO |
WxHxD mm (inch) |
Part number/Details |
FL Switch SFN - Slender shape with variable port count |
FL SWITCH SFN 5TX |
Layer 1 security elements (mechanical prevention of unauthorized acces to port connectors), unmanaged switch, operation within 0(32) - 60(140) degrees celsius (fahrenheit) |
5 |
0 |
30x120x70 |
2891152 |
FL SWITCH SFN 4TX/FX |
s.a. |
4 |
1 |
30x120x70 |
2891851 |
FL SWITCH SFN 8TX |
s.a. |
8 |
0 |
50x120x70 |
2891929 |
FL SWITCH SFN 7TX/FX |
s.a. |
7 |
1 |
50x120x70 |
2891097 |
FL SWITCH SFN 6TX/2FX |
s.a. |
6 |
2 |
50x120x70 |
2891314 |
|
|
Order summary |
Devices |
Description |
RJ45-TP |
FO |
WxHxD mm (inch) |
Part number/Details |
FL Switch LM - Redundant with RSTP and wide temperature range |
FL SWITCH LM 8TX |
Managed switch, redundancy with Rapid Spanning Tree Protocol (IEEE 802.1w), alarm contact for redundant power supply, operation range -40(-8) - 70(158) degrees celsius(fahrenheit) |
8 |
0 |
45x99x112 |
2832632 |
FL SWITCH LM 4TX/2FX |
s.a. |
4 |
2 |
45x99x112 |
2832658 |
|
Products/Hardware/Interfaces and Gateways |
|
SysMik network interfaces |
|
|
IFMS network interfaces
typical applications:
- PC LON interface
- LON interface for laboratory devices
- LON interface for label printers
- LON gateway to simple proprietary protocols based on RS232 or RS485
- LON-Modbus gateway with dedicated application (according to specification) |
|
More... |
|
|
LOYTEC network interfaces |
|
|
LOYTEC NIC network interfaces
For connecting a PC/Laptop to LON networks we are recommending the network interfaces NIC from LOYTEC.
- 32Bit processor for high performance
- Multiplexed Network Interface MNI |
|
More... |
|
|
Echelon network interfaces |
|
|
Echelon network interfaces
SysMik sells additionally also standard network interfaces from the company Echelon with different designs and with different interfaces. |
|
More... |
|
|
Gateways |
|
|
XFM gateways and communication interfaces
SysMik offers with the XFM series free configurable interoperable LON gateways and interfaces with communication tasks (alarms, modem function, gateway between LON networks and serial interfaces). |
|
More... |
|
|
Data Point Connector XFM-LL / EIA-709 |
|
|
Data point connector for non-reactively connecting data points from different TP/FT10 networks:
- safe separation of unions in complex projects
- Data exchange over domain bounds
- Firewall funktionality
|
|
Mehr... |
|
|
Products/Hardware/Display devices |
|
Displays and Operator devices |
|
Product information - Device family DMTX-420
The device family DMTX-420 contains operator- and display devices with LCD text displays (4 rows ?20 characters). Background lighting and contrast are adjustable via software. Several inputs and outputs for connecting of LEDs or external keypads and a beeper are extending the usabilities.
All devices are prepared regarding RAM and FLASH ressources for use with the graphical programming tool IPOCS. But they can be programmed also custom specific with Neuron-C too. Device drivers are available as source library. The available minimum application is designed for displaying text messages (SNVT_str_asc) and confirming these messages via keys.
An instruction for DMTX programming with IPOCS (First Steps in display programming with IPOCS) is available in IPOCS installation or in Software description/programming reference of devices.
|
|
|
DMTX-420-CP |
|
DMTX-420-OEM |
|
Order summary |
Device name |
Specials |
Part number/details |
Programmable displays |
DMTX-420-CP |
Plastic case for wall mounting (150x100x33) |
1402-100023-08-5 |
DMTX-420-OEM |
for custom specific use and extention (98x70x35) |
1402-100023-04-7 |
|
|
|
touch panels TPG
Two TFT touch panels are available for different interfaces:
TPG5-1 and TPG7-1. Both devices are prepared for wall mounting and switch cabinet installation.
The 5.7 " and 7 " devices TPG5-2 and TPG7-1 are Windows-CE touchpanels with Ethernet interface. They can be used as control and visualization clients for controllers with web server such as ICS or JACE, but do not include a JAVA-Virtual Machine for running Java applets.
|
|
|
TPG7-1 |
|
TPG5-2 |
|
Order summary |
Devices |
Description |
Part number/Details |
Touchpanels |
TPG7-1 |
7 inch WindowsCE-TFT-Touchpanel, 64 MiB SDRAM, 32 MiB Flash |
1402-100308-01-4 |
TPG5-2 |
5.7 inch Windows-CE touchpanel |
1402-100325-01-1 |
|
Power supplies and UPS |
|
Power Supply series
凷TEP POWER??flat structural shape for installation distributions
凾RIO POWER??for high currents (up to 40 A upon request)
凲UINT POWER SFB??fuse protection with standard circuit breakers (SFB ... Selective Fuse Breaking)
- modular DIN-rail enclosure
- wide range input 100 ?240 V AC
- output voltage 24 V DC
- short circuit and idle proof
- very reliable (MTBF = 500.000 h)
- operation temperature: -25 癈 (-13 F) - 55 癈 (131 F) at nominal current
- inrush surge current < 15A
- can be connected in parallel |
|
|
STEP-PS/1AC/24DC/0.75 |
TRIO-PS/1AC/24DC/2.5 |
QUINT-PS/1AC/24DC/3.5 |
|
QUINT-DC-UPS/24DC/10 |
MINI-DC-UPS/24DC/2 |
MINI-BAT/24DC/0.8AH |
|
|
Order summary |
Devices |
Description |
.In |
.WxHxD mm |
Part number/Details |
Power supplies without UPS |
STEP-PS/1AC/24DC/0.75 |
Modular installation housing, -25(-13) - 55(131) Grad Celsius (Fahrenheit) at In, inrush surge current < 15A, can be connected in parallel |
0,75A |
36x90x61 |
2868635 |
STEP-PS/1AC/24DC/1.75 |
s.a. |
1,75A |
54x90x61 |
2868648 |
STEP-PS/1AC/24DC/2.5 |
s.a. |
2,5A |
72x90x61 |
2868651 |
STEP-PS/1AC/24DC/4 |
s.a. |
4A |
90x90x61 |
2868664 |
TRIO-PS/1AC/24DC/2.5 |
ambient temperature during operation -25(-13) - 55(131) Grad Celsius (Fahrenheit) at In, inrush surge current < 15A, can be connected in parallel |
2,5A |
32x130x115 |
2866268 |
TRIO-PS/1AC/24DC/5 |
s.a. |
5A |
40x130x115 |
2866310 |
TRIO-PS/1AC/24DC/10 |
s.a. |
10A |
60x130x152,5 |
2866323 |
QUINT-PS/1AC/24DC/3.5 |
With SFBT (Select Fuse Breaking Technology), ambient temperature during operation -25(-13) - 60()140 Grad Celsius (Fahrenheit) at In, low voltage signalisation, inrush surge current < 20A, please note the recommendations related to fuse protection in the data sheets, can be connected in parallel |
3,5A |
32x130x125 |
2866747 |
QUINT-PS/1AC/24DC/5 |
s.a. |
5A |
40x130x125 |
2866750 |
QUINT-PS/1AC/24DC/10 |
s.a. |
10A |
60x130x125 |
2866763 |
|
|
|
Order summary |
Devices |
Description |
In |
WxHxD mm |
Part number/Details |
Power supplies with UPS |
QUINT-DC-UPS/24DC/10 |
Modular UPS combination of 24V power supply (QUINT POWER SFB in consistent structural shape) and UPS module (internal or external accumulator), Un (input / output) 24 V DC, alarm contacts (accumulator failure, accumulator charge, accumulator operation)
UPS 10A (integrated 1.3 Ah battery module) |
10A |
100x130x125 |
2866226 |
QUINT-DC-UPS/24DC/20 |
s.a.
UPS 10A with external battery (3.4 / 7.2 / 12 Ah) |
10A |
66x130x125 |
2866239 |
QUINT-BAT/24DC/3.4AH |
s.a.
Battery, 24V, 3,4 Ah, max. 10A |
10A |
112x145x123 |
2866349 |
QUINT-BAT/24DC/7.2AH |
s.a.
Akku, 24V, 7,2 Ah, max. 25A |
25A |
164x156x123 |
2866352 |
MINI-DC-UPS/24DC/2 |
Power supply and UPS electronic integrated in the device, external accumulator, inrush surge current < 34A (< A2s), can be connected in parallel, alarm contacts (accumulator failure, accumulator charge, accumulator operation)
UPS with integrated power supply, max. 2A |
2A |
67.5x99x107 |
2866640 |
MINI-BAT/24DC/0.8AH |
Battery, 24 V DC, 0,8Ah, max. 5A |
5A |
67.5x99x107 |
2866666 |
MINI-BAT/24DC/1.3AH |
Battery, 24 V DC, 1.3Ah, max. 15A |
15A |
52x130x110 |
2866417 |
|
|