PETER HIRT GmbH传感器
瑞士PETER HIRT GmbH传感器
产品系列:
Overview of all transducers
Table structured overview of all transducers
|
|
|
|
Spring Push
|
|
|
Vacuum Retract
|
|
|
Pneumatic Push Bellow Sealed
|
|
|
Pneumatic Push Air Gap Seal
|
|
|
Cable Exit
|
|
|
Description
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T101F |
|
|
T101V |
|
|
T101P |
|
|
T101L |
|
|
axial |
|
|
halfbridge, ±2 mm measuring stroke |
|
T102F |
|
|
T102V |
|
|
T102P |
|
|
T102L |
|
|
radial |
|
|
|
|
T151F |
|
|
T151V |
|
|
T151P |
|
|
T151L |
|
|
axial |
|
|
fullbridge, ±2 mm measuring stroke |
|
T152F |
|
|
T152V |
|
|
T152P |
|
|
T152L |
|
|
radial |
|
|
|
|
T151F-024 |
|
|
T151V-024 |
|
|
T151P-024 |
|
|
T151L-024 |
|
|
axial |
|
|
LVDT Marposs ® compatible, ±2 mm measuring stroke |
|
T152F-024 |
|
|
T152V-024 |
|
|
T152P-024 |
|
|
T152L-024 |
|
|
radial |
|
|
|
|
T161F |
|
|
T161V |
|
|
T161P |
|
|
T161L |
|
|
axial |
|
|
Mahr ® compatible, ±2 mm measuring stroke |
|
T162F |
|
|
T162V |
|
|
T162P |
|
|
T162L |
|
|
radial |
|
|
|
|
T201F |
|
|
|
|
|
|
|
|
|
|
|
axial |
|
|
halfbridge, ±1 mm measuring stroke |
|
T202F |
|
|
T202V |
|
|
T202P |
|
|
T202L |
|
|
radial |
|
|
|
|
T301F |
|
|
T301V |
|
|
T301P |
|
|
T301L |
|
|
axial |
|
|
halfbridge, ±2 mm measuring stroke |
|
T302F |
|
|
T302V |
|
|
T302P |
|
|
T302L |
|
|
radial |
|
|
|
|
T401 |
|
|
|
|
|
|
|
|
|
|
|
axial |
|
|
halfbridge, mounting system, ±2 mm measuring stroke |
|
T402 |
|
|
|
|
|
|
|
|
|
|
|
radial |
|
|
|
|
T451 |
|
|
|
|
|
|
|
|
|
|
|
axial |
|
|
fullbridge, ±2 mm measuring stroke |
|
T452 |
|
|
|
|
|
|
|
|
|
|
|
radial |
|
|
|
|
T501F |
|
|
T501V |
|
|
T501P |
|
|
T501L |
|
|
axial |
|
|
halfbridge, ±5 mm measuring stroke |
|
T502F |
|
|
T502V |
|
|
T502P |
|
|
T502L |
|
|
radial |
|
|
|
|
T521F |
|
|
T521V |
|
|
T521P |
|
|
T521L |
|
|
axial |
|
|
halfbridge, ±2 mm measuring stroke with 8 mm after electrical zero, setting 1:2 |
|
T522F |
|
|
T522V |
|
|
T522P |
|
|
T522L |
|
|
radial |
|
|
|
|
T523F |
|
|
T523V |
|
|
T523P |
|
|
T523L |
|
|
axial |
|
|
halfbridge, ±2 mm measuring stroke with 8 mm after electrical zero, setting 1:1 |
|
T524F |
|
|
T524V |
|
|
T524P |
|
|
T524L |
|
|
radial |
|
|
|
|
T801 |
|
|
|
|
|
|
|
|
|
|
|
axial |
|
|
halfbridge, ±2 mm measuring stroke |
|
T802 |
|
|
|
|
|
|
|
|
|
|
|
radial |
|
|
|
|
T851 |
|
|
|
|
|
|
|
|
|
|
|
axial |
|
|
fullbridge, ±2 mm measuring stroke |
|
T852 |
|
|
|
|
|
|
|
|
|
|
|
radial |
|
|
|
|
DC-Transducer
T-series transducer with in-cable box signal conditionning, signal output +/- 10 VDC for full spectification displacement
application
|
the same as T-series transducers
|
body diameter
|
8h6
|
dimension
|
in-cable box 58 x 35 x 16 mm
|
supply voltage
|
supply voltage 5, 12 oder 24 VDC (+/- 10%) (please specify with order)
current consumption 120, 50 or 25 mA
|
signal output
|
+/- 10 VDC for full specification displacement
(other specifications on request)
|
connection
|
supply and signal output: cable PVC, length 1 m, prepared wires
transducer connected fix to the box, cable PUR, length 2 m
|
models
|
Transducer T101/T102, measuring stroke +/- 1 mm
Transducer T201/T202, measuring stroke +/- 1 mm
Transducer T301/T302, measuring stroke +/- 2 mm
Transducer T501/T502, measuring stroke +/- 5 mm
Transducer T521/T522, measuring stroke +/- 2 mm
Transducer T523/T524, measuring stroke +/- 1 mm
|
examples for ordering
|
T101F as DC-Transducer with supply voltage 12V, signal output +/- 10V and measuring stroke +/- 1 mm:
T101FDC12B10W1
|
drawing
|
|
T-Modul
signal conditionning electronic for halfbridge transducers, mountable into frontpanels, output signal +/- 10 or +/- 5 VCD, for full specification displacment for the transducer
application
|
signal conditionning for T-series transducers
for TESA® compatible halfbridge transducers
|
dimension
|
31 x 50 mm (no casing)
|
fixing
|
with threaded ring, hole diameter for socket fixing 18 mm
|
supply voltage
|
supply voltage 5, 12 or 24 VDC (+/- 10%) (please specify with order)
current consumption 120, 50 or 25 mA
|
signal output
|
+/- 10 VDC for tranducers
T101/T102, measuring stroke +/- 1 mm
T201/T202, measuring stroke +/- 1 mm
T301/T302, measuring stroke +/- 2 mm
T401/T402, measuring stroke +/- 1 mm
T501/T502, measuring stroke +/- 5 mm (Standard Setting 1:10)
T521/T522, measuring stroke +/- 2 mm
T523/T524, measuring stroke +/- 1 mm
other specifications upon request
|
connection
|
supply and signal: pads on PCB
transducer: socket 5 pin, 270°
|
transducer supply
|
3 V +/- 0.5% RSM / 13 kHz +/- 5%
|
sensitivity
|
73.75 mV/(Vmm) (into R = 2 kOhm +/- 0.1%)
|
examples for ordering
|
T-module with supply voltage 12 V, signal output +/- 10V and measuring stroke +/- 1 mm for a T101:
TMT101S12B10W1
|
drawing
|
|
Cable Module
signal conditionning for T-series transducers, socket to accept transducer plug, output signal ±10 VDC or ±5 VDC, for full specification displacement of the transducer
application
|
signal conditionning for T-series transducer
for TESA® compatible halfbridge models
|
dimension
|
box 73 x 51 x 25 mm
|
supply voltage
|
supply voltage 5, 12 or 24 VDC (+/- 10%) (please specify with order)
current consumption 120, 50 or 25 mA
|
signal output
|
+/- 10 VDC for transducer
T101/T102, measureing stroke +/-1 mm
T201/T202, measureing stroke +/-1 mm
T301/T302, measureing stroke +/-2 mm
T401/T402, measureing stroke +/-1 mm
T501/T502, measureing stroke +/-5 mm (Standard setting 1:10)
T521/T522, measureing stroke +/-2 mm
T523/T524, measureing stroke +/-1 mm
other specifications upon request
|
connection
|
supply and signal: cable PVC, length 1 m, prepared wires
Transducer: socket 5 pin, 270 °
|
transducer supply
|
3 V +/- 0.5 % RMS /13 kHz +/-5%
|
sensitivity
|
73.75 mV/(Vmm) (an R= 2 kOhm +/- 0.1 %)
|
examples for ordering
|
Cable Module with supply voltage 12 V, signal output +/- 5 V and measuring stroke +/- 2 mm for a T101:
KMT101S12B5W2
|
drawing
|
|
DIN-Rail Module
signal condition electronic for halfbridge transducers, housed in DIN-Rail case, signal output +/- 10 VDC or +/- 5 VDC, for full specification displacement of the transducer
application
|
signal conditionning for T-series transducers
for TESA® compatible halfbridge transducers
|
dimension
|
86 x 35 x 58 m (height from rail top surface)
|
supply voltage
|
supply voltage 5, 12 or 24 VDC (+/- 10%) (please specify when ordering)
current consumption 120, 50 or 25 mA
|
signal output
|
+/- 10 VDC for transducer
T101/T102, measuring stroke +/- 1 mm
T201/T202, measuring stroke +/- 1 mm
T301/T302, measuring stroke +/- 2 mm
T401/T402, measuring stroke +/- 1 mm
T501/T502, measuring stroke +/- 5 mm (Standard setting 1:10)
T521/T522, measuring stroke +/- 2 mm
T523/T524, measuring stroke +/- 1 mm
other spezifications upon request
|
connection
|
supply and signal: screw terminals
transducer: socket 5 pin, 270°
|
transducer supply
|
3 V +/- 0.5 RMS / 15 kHz +/- 5%
|
sensitivity
|
73.75 mV (Vmm) (an R = 2 kOhm +/- 0.1 %)
|
examples for ordering
|
DIN-Rail Module with supply voltage 12 V, signal output +/- 5 V and measuring stroke +/- 2 mm for a T101:
DMT101S12B5W2
|
Zeichnung
|
|
MICRON-Switch
small signal switch with highest repeatability of the crossover position
application
|
reference switch for position stages
precision end stops
reference settings etc.
|
repeatability
|
+/- 0.0005 mm
|
overtravel
|
1.5 mm (longer overtravel upon request)
|
operation force
|
0.7 N (other values upon request)
|
temperature range
|
-20 to +70 °C, storage and opertation
|
current rarting
|
50 mA
|
lifetime
|
> 10 Mio. cycles
|
mounting position
|
any
|
function
|
NC (normally closed)
|
cable
|
PUR, length 1m, prepared wires
|
wires
|
2 x 0.14 mm2
|
body OD
|
M8 x 0.5
|
case material
|
stainless steel (1.4305)
|
clamping nuts
|
2 pieces included
|
drawing
|
|
Accessories
Tips with fixing thread M2.5
TN10W
|
|
|
|
TN12
|
|
|
|
TN20
|
|
|
|
TN30W
|
|
|
|
TN70
|
|
|
|
TN91 X = 15mm
TN93 X = 40mm
|
|
Fixing elements
T100/630 clampbush
|
|
|
|
T100/631 clampscrew
|
|
Pneumatic Connection
T100/481 nipple, rotaing
|
|
|
|
Comparison
standard T100/480
rotating T100/481
|
|
Extension Cables
T100/781, 1,0 meter
T100/782, 2,5 meter
T100/785, 3,3 meter
T100/787, 7,5 meter
T100/790, 10 meter
|
|
|
|
|