ILMVAC GMBH真空泵
德国ILMVAC GMBH真空泵
产品系列:
Scroll pumps
Rotary Vane Pumps
Diaphragm Pumps
Turbomolecular Pumps
Oil Diffusion Pumps
For the production of a vacuum from the rough- into the high vacuum range different pumping principles are used. So e.g. for the - rough vacuum range = diaphragm pumps, - rough- and fine vacuum range = scroll and rotary vane pumps, - high and ultra high vacuum range = turbomolecular- and oil diffuion pumps (in combination with diaphragm-, scroll- and rotary vane pumps as fore-pumps)
Vacuum Diaphragm Pump Systems
|
Laboratory Vacuum Systems LVS standard
Laboratory Vacuum Systems LVS economic (en)
Laboratory Vacuum Systems LVS ecoflex (ef)
Cascade Diaphragm Pump Systems univac
ILMVAC GmbH strives not only to develop professional vacuum engineering solutions for standard applications. In addition we are greatly expirenced in the execution of purpose built turnkey projects. We are pleased to offer our konwledge and experience and to work with our customers to deliver innovative and economical solutions for industry and research. Whether you require leading edge replacements for existing equipment or practical solutions for new processes, we are part of your team. To illustrate our breadth of system build experience: - leak testing systems - vacuum plasma systems - special pump systems
Vacuum Pump Systems / Plants
|
Combination Pump Systems chemvac Roots Pump Systems Turbomolecular Pump Systems Oil Diffusion Pump Systems Special Pump Systems / Plants
Vacuum Aspiration / Filtration
|
biovac
fluivac
biocont
ILMVAC aspiration systems provide for the safe transfer of liquid in all sectors of industry and in the laboratory. The use of different pipet tips allows for safe and efficient removal of numerous fluids. The optional "filter head" expansion sets enable these units to be used for filtration tasks.
Vacuum Aspiration / Filtration
|
biovac
fluivac
biocont
ILMVAC aspiration systems provide for the safe transfer of liquid in all sectors of industry and in the laboratory. The use of different pipet tips allows for safe and efficient removal of numerous fluids. The optional "filter head" expansion sets enable these units to be used for filtration tasks.
Vacuum Aspiration / Filtration
|
biovac fluivac biocont
ILMVAC aspiration systems provide for the safe transfer of liquid in all sectors of industry and in the laboratory. The use of different pipet tips allows for safe and efficient removal of numerous fluids. The optional "filter head" expansion sets enable these units to be used for filtration tasks.
The anaerobic gassing system "anavac 104" consists of a control device as a unit together with a diaphragm pump, a reaction gas container, and flushing gas system. The required vacuum, gassing pressure and the number of gassing cycles have a fixed set-ting. Over the interface RS 232 these can be changed easily by means of a PC or laptop as required. A detailed description is to be found in the manual. Via the start button the fully automatic process is released. The ventilation with the reaction gas follows the evacuation of the attached anaerobic container up to the adjusted pressure. The preset number of cycles is repeated automatically. With rapid-action couplings the system can be attached to and separated from the reaction gas container. The anavac 104 is supplied completely installed. The aeration gas and the pressure-reducing valve are not included in the scope of delivery.
Products |
Order No. |
Anaerobic Gassing System
anavac 104 T
115/230V 50/60Hz |
112017 |
The following components are chemically resistant. The valve housings are made of polypropylene. We produce "netvac" adapters and connectors for built-in components in furniture, media channels and columns on request. Legend: M = vacuum connections point manual E = vacuum connections point automatic R = rear panel connections + = with Kalrez - check valve
Products |
Dimensions (W/D/H)
[mm] |
Order No. |
netvac set
M01+ / R01 |
92/69/69 |
700531 |
netvac set
M01+ / R04 |
- |
700531-03 |
netvac set
M02+ / R01 |
55/40/150 |
700532 |
netvac set
M02+ / R04 |
- |
700532-03 |
netvac set
M03 / R01 |
98/69/158 |
700533 |
netvac set
M04+ / R01 |
95/40/75 |
700534 |
netvac set
M04+ / R04 |
- |
700534-03 |
netvac set
M05+ / R01 |
124/69/158 |
700535 |
netvac set
M05+ / R04 |
- |
700535-03 |
netvac set
M06 / R01 |
- |
700536 |
netvac set
M07+ / R01 |
- |
700537 |
netvac set
M07+ / R04 |
- |
700537-03 |
netvac set
M08+ / R01 |
- |
700538 |
netvac set
M08+ / R04 |
- |
700538-03 |
netvac set
E01+ / R01 |
- |
700541 |
netvac set
E01+ / R04 |
- |
700541-03 |
netvac Check valve
M12 |
- |
700440 |
Vacuum Measurement and Control
|
Rough Vacuum Gauges 1000 - < 1 mbar Fine Vacuum Gauges 1 - 10^-3 mbar Multi-Range and High Vacuum Gauges Vacuum Controllers 1100 to 1 mbar
The total range of scientifically useful vacuum extends from approx. 1000 mbar (atmospheric pressure) down to 10^-12 mbar, the ultra high vacuum range. The instruments for measuring the pressure are vacuum gauges. No one physical measuring technique covers the whole vacuum/pressure range. Particular sensors and gauges must be used for parts of the whole range, rough, fine, high and ultra high vacuum. These systems are also offered in combination as multi-range vacuum gauges for covering multiple measuring ranges. Rough vacuum gauges Measuring range: atmospheric to 1 mbar Besides the traditional vacuum gauges with mechanical sensors (e.g. Bourdon, capsule gauge) diaphragm manometers with electronical diaphragm sensors are well established (Piezo and capacitance gauges). The pressure to be measured is separated by a diaphragm from a reference vacuum and compared to the latter. The movement of the diaphragm is registered either by a piezo resistive system or the diaphragm is part of a capacitor (capacitance vacuum system). For improved chemical resistance the diaphragm is often made of aluminium oxide ceramic. The pressure measurement is independent of the type of gas.
Vacuum Devices Accessories
|
for Scoll Pumps for Rotary Vane Pumps and chemvac for Diapragm Pumps and -Pump Systems for Distillation, Aspiration, Filtration, Anaerobic for Turbomolecular Pumps and -Pump Systems for Measuring Gauges, Controller and Leak Detector Mains Connection Cables Oils for Vacuum Pumps
|